Click or drag to resize

DHMDeviceBase Class

Base class for the DHM Device
Inheritance Hierarchy

Namespace:  LynceeTec.DHM
Assembly:  LynceeTec.DHM (in LynceeTec.DHM.dll) Version: 8.1.17212.0 8_1_dev af417e8, built 2019-10-03 13:47:41 UTC
Syntax
public abstract class DHMDeviceBase : IDHMDevice, 
	IDisposable

The DHMDeviceBase type exposes the following members.

Properties
  NameDescription
Public propertyCamera
Gets the camera controller. Access to the camera is done through this property.
Public propertyHoloSource
Gets a hologram source which can provide both holograms coming from the drive and from the camera.
Public propertyIsHardwareAvailable
Gets a value indicating whether the enabled physical hardware was detected and is available.
Public propertyIsLoggedIn
Gets a value indicating whether a user is logged in.
Public propertyLaserSourcesController
Gets the laser sources controller. Access to each laser source is done through this property.
Public propertyMotors
Gets the motors manager. Access to each motor is done through this property.
Public propertyOperationMode
Public propertySerialNumber
Gets the serial number of the DHM
Public propertyStage
Gets the stage controller. Access to the camera is done through this property.
Public propertyTurretManager
Gets the turret manager. Access to each turret is done through this property.
Top
Methods
  NameDescription
Public methodDispose
Releases all resources used by the DHMDeviceBase
Public methodInitDhm
Initializes the DHM hardware components in parallel. Only available after logging in. (See Login(IUser)) Asynchronous function.
Public methodInitDhmSerial
Initializes the DHM hardware components one after the other. Only available after logging in. (See Login(IUser)) Asynchronous function.
Public methodLoadConfig(IDHMConfiguration, ISampleInfo, IProgressReporter)
Loads a configuration and sets the hardware parameters accordingly. Can only be called after initialization is done. Asynchronous function.
Public methodLoadConfig(IDHMConfiguration, DictionaryMotorizedDevicesType, Single, IProgressReporter)
Loads a configuration and sets the hardware parameters accordingly. Can only be called after initialization is done. Asynchronous function.
Public methodLoadSampleConfig
Loads the sample configuration. Can only be called after initialization is done. Asynchronous function.
Public methodLogin
Logs an authenticated user in the DHM device.
Public methodLogout
Logs out the user and resets the initialization of the device
Public methodUnloadConfig
Unloads the measurement configuration. This does not modify anything in the hardware, but reset fields
Top